Dissolved Oxygen Analyzer DOM 5.0
Measurement range DO: 0-20 mg/L, 0-20 ppm; Temperature: 0-45℃
Measurement Accuracy DO: ±3% of the measured value, Temperature: ±0.5℃
Calibration Air automated calibration, sample calibration
Output 2-way 4-20mA
Relay Setting three-way relays,
Communication protocol MODBUS through RS485
DOM 5.0 Dissolved Oxygen Analyzer adopts fluorescence method to measure dissolved oxygen.The cap of the sensor is coated with a luminescent material. Blue light from an LED illuminates the luminescent chemical. The luminescent chemical instantly becomes excited and releases red light. The time and intensity of red light are inversely proportional to the concentration of oxygen molecules, So the concentration of oxygen molecules is calculated.
Some Features;
· The sensor adopts new type of oxygen sensitive membrane,with NTC temperature compensated
function,whose measurement result has good repeatability and stability.
·Won’t produce oxygen consumption when measuring and no requirement of flow rate and stirring.
· Breakthrough fluorescence technology,without membrane and the electrolyte and almost not need
maintenance.
·Built-in self-diagnosis function to ensure the accuracy of data.
·Factory calibration,not need calibration for a year and can carry out field calibration.
Application Areas;
-Waste water treatment plants:
·O2 control in the aeration basin
·Process water treatment and monitoring
-Water works:
·Status monitoring of drinking water (oxygen enrichment, corrosion protection, etc.)
·Water quality monitoring in rivers, lakes or seas
-Utilities of all industries:
·O2 control in the biological treatment
·Process water treatment and monitoring
-Fish farming:
·O2 control for optimum growth conditions
-Wastewater treatment plants:
·O2 control in the aeration basin
·Process water treatment and monitoring
-Water works:
·Status monitoring of drinking water (oxygen enrichment, corrosion protection, etc.)
·Water quality monitoring in rivers, lakes or seas
-Utilities of all industries:
·O2 control in the biological treatment
·Process water treatment and monitoring
-Fish farming:
·O2 control for optimum growth conditions
Measurement range DO: 0-20 mg/L、0-20 ppm; Temperature: 0-45℃
Measurement Accuracy DO: ±3% of the measured value; Temperature: ±0.5℃
Pressure range: ≤3 Bar
Calibration Air automated calibration, sample calibration
Main material Body: SUS316L + PVC(fresh water), Titanium alloy (marine)
O-ring: fluorine rubber, Cable: PVC
Power supply AC:100-240VAC (50/60HZ)DC: 9~36VDC
Output 2-way 4-20mA
Relay Setting three-way relays,programmed response parameter and response value.
Communication protocol MODBUS RS485
Storage temperature -15-65℃
Measuring temperature 0-45℃
Dimensions Sensor: Dia. 55mm*L 342mm
Transmitter: 145*125*162mm(L*W*H)
Weight Sensor: 1.85KG, Transmitter: 1.35KG
Protective rate Sensor: IP68/NEMA6P; Transmitter: IP65/ NEMA4X
Cable length Standard: 10m, the maximum may be extended to 100m