Aktek Endüstriyel

İletişim Bilgileri

IMP+ Ultrasonik Seviye Transmitteri

  • Kompakt bağımsız seviye ölçümü
  • IP67 derecelendirmesinden ödün vermeden kalibre edin
  • Basit menü ledli kurulum
  • Yüksek güç ve dar ışın açıları

The IMP+ non-contacting ultrasonic sensor is designed to be used wherever you need an accurate and reliable level measurement. Its digital echo processing means the IMP+ is perfect for slurries, liquids, or anywhere you need a display telling you the level or analog output to interface with your site control system or drive a display.

There are several measurement ranges available from 0 m to 10 m and each can be wired for 2 or 3-wire operation. All options feature an LCD display and digital temperature measurement and compensation. When combined with Pulsar’s PC Suite, users are able to download, analyze and store echo profiles, set up the IMP’s parameters, install the new firmware to your IMP, and add a flow curve to be able to configure level to flow linearization.

• Tank Seviyesi Uygulamaları
• Kimyasal Dozajlama
• Basit Seviye Göstergesi
• Açık ve Kapalı Gemi Seviyesi
• Katı Madde Seviyesi Göstergesi

Spec: Description:
Dimensions 186 mm (H) x 133 mm (D) (5.24 in (H) x 7.32 in (D))
Cable Entry: 2 off cable glands 4.5 mm to 10 mm (0.18 in to 0.39 in); Torque to 2 NM
Mounting: IMP3 - 3 m (10 ft) version: 1.5 in BSP/NPT
IMP 6 - 6 m (20 ft) version: 1.5 in BSP/NPT
IMP10 - 10 m (33 ft) version: 2 in BSP/NPT
Suits BSP & NPT, parallel and tapered
Weight Nominal 1kg (2.2 lb)
Enclosure Protection IP67
Temperature (Process) -4 0°C to +65 °C (-40 °F to +149 °F )
Temperature (Ambient) -40 °C to +80 °C (-40 °F to +176 °F)
Input Voltage Range 11-30 V, 3.5-22 mA
Accuracy ±0.25% or 6 mm (0.24 in) whichever is greater
Resolution ±0.1% or 2 mm (0.08 in) whichever is greater
4-20mA Outputs Resolution 5 μA; both active and passive outputs
Temperature Compensation Via internal temperature sensor 0.5 °C (± 32.9 °F) accuracy. Level and volume conversion are installed allowing linearisation for tank shapes.
PC Interface All parameters can be accessed and changed through PC Suite software. Echo traces may be viewed on-screen.
Options
Option: Description:
Variants IMP Lite
IMP I.S.
Configurations 2-Wire or 3-Wire
Beam Angle (-3 dB half power) IMP3: ‹10° inclusive
IMP6: ‹10° inclusive
IMP10: ‹10° inclusive
Operating Frequency IMP3: 125 kHz
IMP6: 75 kHz
IMP10: 41 kHz
Measurement Range IMP3: 0.2 m to 3 m (0.66 ft to 10 ft)
IMP6: 0.3 m to 6 m (0.98 ft to 20 ft)
IMP10: 0.3 m to 10 m (0.98 ft to 33 ft)
Software IMP PC

Onaylar;

  • IP67
  • Intrinsically Safe Version Available
  • CE

Su

Atıksu

Yiyecek

Petrokimya

İçecek

Petrol & Gaz

Enerji

Kağıt

×
Merhaba, bilgi almak istiyorum.