Ultrasonic Flowmeter TFM4100W
- Non-contact measurement with sensors clamped outside the pipe
- Flow measurement in pipes DN15…DN6000
- 4-20 mA, Pulse, Relay outputs and MODBUS communication
- Can be used as a calorimeter with Pt-100 inputs
Ultrasonic Flowmeter / Calorimeter TFM3100-F1
Ultrasonic Flowmeter / Calorimeter TFM3100 relatively free of air bubbles, such as chemicals, oils and water. It is mounted on the outer surface of all types of pipes that can transmit ultrasonic sound to measure the flow rate of clean liquids. Installation of clamp sensors from outside the pipe is done without stopping the flow. So pressureç reduced and no clogging occurs. It saves labor and time.
The measurement system consists of a pair of ultrasonic sensors acoustically coupled from outside the pipe. The server unit has a microprocessor, analyzes the signals sent and received from the sensors, and sends the signal to the control and process systems through an interface.
Application Areas:
-
- Water & Wastewater
- Drinking Water
- River Water
- Coolant
- Demineralized Water
- Crude Oil
- Mineral Oil
- Hydroelectric, Fire Extinguishing Stations
- Food, Beverage Industry
- Flow Balancing
- Glycol solution
- Hydraulic Oil
- Diesel & Fuel Oil
- Chemicals
- Petrochemicals
- Heating and Cooling Systems
- Fire suppression systems
Application Areas:
-
- Water & Wastewater
- Drinking Water
- River Water
- Coolant
- Demineralized Water
- Crude Oil
- Mineral Oil
- Hydroelectric, Fire Extinguishing Stations
- Food, Beverage Industry
- Flow Balancing
- Glycol solution
- Hydraulic Oil
- Diesel & Fuel Oil
- Chemicals
- Petrochemicals
- Heating and Cooling Systems
- Fire suppression systems
Operation: For clean liquids containing less than 1% solid particles and gas bubbles in fully filled pipes
Configuration : With built-in keypad
Transmitter:
Precision: % better than ±1, Linearity: %±0.5, Stability: %± 0.2
Supply : 24 VDC
Çoutputs : 4-20 mA, Pulse, Relay
Inputs:3 channels 4-20mA Analog, 2 channels 3-wire resistor. (PT100)
Communication : RS485, MODBUS, M-BUS
Operating temperature : -20...50°C
Protection: IP 20
Dimensions: 90 x90 x 36 mm
Sensors
Pipe diameter: DN 15...6000 mm inside For diameter pipes
Pipe Materials: Any type of metal or plastic material that can transmit ultrasonic sound. with pipe material (carbon steel, stainless
Operating Temperature: For Standard Sensors; -30…+90o C (TL-1, TM-1, TS-2)
For high temperature sensors; -30…+160o C (HTM-1, HTM-1)
Sensor Mounting Kit: Includes stainless steel mounting clamps and acoustic bonding gel
Sensor Cable: Standard 5 m