Aktek Endüstriyel

Contact Us

Telemetry Solutions

  • Power your laptop with the power of LTE CAT M1 / NB-IoT connectivity. Access measurement data remotely at any time via your computer, PC or mobile device.
  • Automatically store measurement data in the cloud for viewing or reporting and ensure measurements are “normal” Configure alerts for you or your operators if levels are exceeded.
  • Save time and money by seeing how your measurement systems work without having to be where the devices are installed.
  • Get an infrastructure-independent measurement solution perfect for remote locations. RANGER is battery operated and provides power to 2-wire sensors for measuring. provides. Or combine the Ranger with a meter that can be operated with 12 VDC and you have your metering solution. Operate with a combination of batteries and solar.

Product Description

SignalFire Wireless Telemetry RANGER and Pulsar Metering solutions are powerful for remote monitoring of flow, level or volume. It is a combination.

Pulsar measurement Combining with SignalFire's wireless telemetry products means you can:

  • Power your laptop with the power of LTE CAT M1 / NB-IoT connectivity. Access measurement data remotely at any time via your computer, PC or mobile device.
  • Automatically store measurement data in the cloud for viewing or reporting and ensure measurements are “normal” Configure alerts for you or your operators if levels are exceeded.
  • Save time and money by seeing how your measurement systems work without having to be where the devices are installed.
  • Get an infrastructure-independent measurement solution perfect for remote locations. RANGER is battery operated and provides power to 2-wire sensors for measuring. provides. Or combine the RANGER with a meter that can be operated with 12 VDC and you have your measurement solution. Operate with a combination of batteries and solar.

Level or Volume Measurement

Pulsar Measurement dBi, REFLECT™ or SignalFire RANGER with Ultra Controller

With built-in batteries, RANGER powers dBi. and will measure anywhere and anytime, at easily user-configured intervals via a local connection to the SignalFire Toolkit PC software, or via the SignalFire Cloud. Or pair dBi-Modbus (dBi-M) with the RANGER with Modbus input and take advantage of serial communication to return multiple measurement values from dBi-M with just a 4-wire connection.

Power the RANGER, REFLECT™ with built-in batteries. and will measure anywhere and anytime at easily user-configured intervals via a local connection to the SignalFire Toolkit PC software or via the SignalFire Cloud. Use REFLECT in applications with harsh conditions, such as foam or steam, where ultrasonics may not be the ideal technology.

Pairing any of the Ultra controllers with a SignalFire RANGER gives you the opportunity to view and manage your application anytime, anywhere. With internal batteries, RANGER can run on local power. It gives you an indication of the performance of the Ultra controller regardless of its source, or by running the RANGER from the same VDC source as the Ultra it is possible to transmit data to the cloud more frequently without worrying about battery drain. The RANGER can be configured with a Modbus input for connection with the Ultra Controller or the Ultra controller plus other installed equipment, making the RANGER powerful. It makes it an integration tool.

Flow Measurement in Pipe

Pulsar Measurement TTFM 6.1  or DFM 6.1 with SignalFire RANGER

Whether installed on-site or in a remote location, powerful a telemetry-enabled flow measurement solution Combine TTFM 6.1 with RANGER for RANGER, debiyi  It can be configured with only a 4-20mA input for monitoring, as well as digital inputs for monitoring flow totals and alarms. Or, configure the RANGER with a Modbus input to take advantage of the ability to bring multiple measurements and diagnostics on just one pair of cables. RANGER makes it easy to view, report and control your application from anywhere, anytime.

By combining DFM 6.1 with RANGER, you get a powerful telemetry-enabled system for difficult fluids, whether installed in your facility or in a remote location. A flow measurement solution. get it. RANGER,  flow  It can be configured with only a 4-20mA input for monitoring, as well as digital inputs for monitoring flow totals and alarms. Or, to take advantage of the ability to deliver multiple measurements and diagnostics on just one pair of cables. Configure RANGER with a Modbus input. RANGER makes it easy to view, report and control your application from anywhere, anytime.

Flow Measurement in Open Channel (With Weirs and Weirs)

Pulsar Measurement Ultra 4 or  OCF 6.1 with SignalFire RANGER

No telemetry-enabled open channel flow measurement system can offer as much accuracy and reliability as Ultra 4 and RANGER. RANGER's browser-based cloud interface allows the user to view their data anytime, anywhere. Also, the product You can easily export data reports to meet activity requirements without having to handle them. RANGER is the perfect data collection and reporting solution whether your meter is installed on site or remotely.

OCF 6.1 combined with SignalFire RANGER provides no telemetry-enabled  The open channel flow measurement system couldn't be easier to install and use. RANGER's browser-based cloud interface allows the user to view their data anytime, anywhere. Also, the product You can easily export data reports to comply with activity requirements without having to handle them. RANGER is the perfect data collection and reporting solution whether your meter is installed on site or remotely.

Flow Measurement in Open Channel (Without Weir or Weir)

Pulsar Measurement AVFM 6.1  or MicroFlow-i and  SignalFire RANGER with dBi

When used with AVFM 6.1, the SignalFire RANGER can be configured with just a single 4-20mA input to monitor flow at user-defined intervals, or you can also configure the RANGER with multiple 4-20mA inputs to monitor flow, level and speed. You can order as.
RANGER can also be configured with a Modbus input to monitor multiple measurements and diagnostic points on a pair of cables.
Use RANGER with its own built-in batteries for independence from AVFM, or purchase with 12-24VDC input for remote locations using battery and solar power. RANGER's browser-based cloud interface allows the user to view their data anytime, anywhere. Also, the product You can easily export data reports to comply with agency requirements without having to handle them.

MicroFlow-i, dBi and SignalFire RANGER, completely contactless, powerful. an area-velocity solution. helps create. RANGER can feed and take measurements independently of both sensors, making this combination a great solution for completely off-grid area velocity flow measurement applications. turns it into ;m. RANGER's browser-based cloud interface allows the user to view their data anytime, anywhere. Also, the product activity without having to hold it in your hand. You can easily export data reports to comply with your requirements.

Find your ideal solution. To find  Contact us.

Physical Properties
Feature: Description:
Operating Temperature: -40 to +185°F (-40 to 85°C)
Feed: Battery Pack: Four D-cell Lithium Thionyl Chloride, 76AHr
Optional solar power
Optional  10-30Vdc  login
Battery Life: Up to 8 years
Data Interface: LTE CAT M1 / NB-IoT, auto selectable
SparkPlug B messaging
Body: Industrial polycarbonate  UV rated, IP64
Electrical Connection: Plug-in terminal block, 16-30AWG screw terminals
Weight: 0.6kg
Estimated Monthly Data Usage: Depends on Check-in Interval

 

1  min. = 27MB
5 min= 5.4 MB
15 min. = 1.08 MB
60min.= 0.27 MB

Security Ratings: Class 1 Division 2  certified Groups A, B,C, D. Temperature code T5.  CSA C22.2 No. 213:2017 Certified,                  UL 121201:2017 compliant, CE Approved

Optional:

  • 2AI1DI Module - 2 additional analog inputs and 1 additional digital input
  • Modbus Module - Modbus RTU - RS485  up to 8 slaves, 32 total registers (Read/Write)
  • HART Module - 1-15 HART sensors  ÇSupports in multi-transmission  mode

Approvals:

  • Class 1 Division 2 Certified, Group A, B,C, D. Temperature code T5
  • Certified CSA C22.2 No. 213:2017
  •  UL 121201:2017 Compliant
  • CE Approved

Water

Wastewater

Food

Petrochemicals

Beverage

Oil and Gas

Power

Paper

×
Hello, I want to get information.