Quantum 2 is a fully-featured pump controller, using Pulsar’s non-contacting ultrasonic technology including DATEM digital echo discrimination to provide solid performance and sophisticated level management. The unit includes 10 relays (digital outputs) and 7 digital inputs and has optional RS485 communications allowing for Modbus, and optional Profibus DP V0 and V1; enabling the status of the unit to be monitored and the controller to be programmed remotely.

Digital inputs allow the unit to respond to ‘no flow’ conditions and the Quantum 2 is able to automatically reset pumps in case of failure, saving unproductive maintenance trips to the site and freeing up staff time for more important work. The Tariff Guard routines, which are common to all intelligent controllers, ensure that energy costs are minimized through periods of maximum electricity tariff, while the Quantum’s unique ‘time to spill alarm’ protects critical pumping stations from uncontrolled overflow. The Tariff Guard All intelligent pump controllers by Pulsar Measurement operate in a highly intelligent and predictive manner: with the objective to have a ‘full’ or ‘empty’ well as the tariff changes.

The liquid level and the inflow rate is continually measured and assessed in the well. Both these variables are then related to the time the next tariff change occurs. If the next tariff charge is for a higher cost rate, the well will be filled first to enable pump down immediately prior to moving onto the higher tariff charge. This then provides maximum storage capacity in the well during the higher tariff period, once in the lower tariff cost period the level is pumped down as normal using the minimum number of pumps.

The level and inflow condition of the well is continuously monitored to optimize the liquid level and intelligently control the purpose of the pumps according to the impending tariff change. By doing this, high tariff charge pumping may be reduced significantly, or avoided entirely, to provide real cost savings on pump energy charges, especially during higher energy cost periods.

• Pump Station Monitoring
• ‘Time to Spill’ Alarms
• Well Monitoring
• Pump Efficiency Monitoring;
• Automated Pump Reset
• Predictive Maintenance

General Specifications
Spec: Description:
Controller Body Dimensions 200 mm x 112 mm (7.87 in x 4.41 in) front, 165 mm x 105 mm (6.49 in x 4.13 in) cut-out
Weight Nominal 1.3 kg (2.9 lbs)
Case Material Stainless steel and polycarbonate, flame resistant to UL94 V0
Power Supply 115 V AC +5% / -10% 50/60 Hz, 220 V AC +5% / -10%, 18-36 V AC
Volt-free Contacts 10 total. Relays 1-5 form C (SPDT) 5 A, 220 V AC. Relays 6-10 form C (SPDT) 3 A, 220 V AC
Digital Inputs 7 NO or NC with 24 V DC internal supply, available max. 20 mA
Analog Output (adjustable) 2 x Isolated output of 4-20mA or 0-20mA into 500 Ω (user-programmable and adjustable) 0.1% resolution
Analogue Input Isolated input for the loop-powered device. 4-20mA source. NB: Active input on request
Serial Output RS232 via RJ11 port
Display 6 digits plus 12 character text, plus bar graph with direction indicators, remote communicator identifier, and program/run/test mode indicators
Options
Option: Description:
Data Logger Large on-board data-logging facility (256 kb)