Aktek Endüstriyel

Contact Us

MicroFlow Non-Contact Flow Sensor

  • Non-contacting
  • Cost-effective
  • Lightweight, compact and robust design
  • Minimal installation costs
  • No interuption to process
  • Maintenance Free
  • ATEX Ex mb Zones 1 & 2 approval
  • RS485 Modbus

MicroFlow delivers accurate and repeatable velocity flow measurement, either as a stand-alone device or as part of a complete area velocity flow meter system. Velocity x area calculation using MicroFlow provides a cost-effective flow measurement option compared to the installation of a primary measurement device, such as a flume or weir, and provides a viable alternative where the hydraulics of a site does not allow for a restriction of the channel.

For channels less than 1.5 m (4.42 ft) wide, MicroFlow can operate as a stand-alone sensor, or be combined with the Velocity Interface controller. For channels that are more than 1.5 m (4.92 ft) wide, MicroFlow can be combined with a dBMACH3 flow transducer and a FlowCERT controller, more than one MicroFlow sensor is often needed – in such cases, these sensors can be combined with a dBMACH3 flow transducer and an Ultimate Controller.

• Effluent Flow
• Open Channel Flow
• Applications with No PMD
• Area Velocity
• Water & Wastewater
• Quarry & Mining

General Specifications
Spec name: Description:
Sensor Body Dimensions: 90 mm x 140 mm (3.54 in x 5.51 in)
Weight: 1 kg (2.2 lbs)
Sensor Body Material: Valox 357
Maximum Separation: Up to 500 m (1,640 ft)
Max. and Min Temperature (Electronics): -20 °C to +60 °C (-4 °F to +140 °F)
Velocity Range: 0.2 m/s to 6 m/s (0.66 ft/s - 19.7 ft/s)
Optimum Installation: Install at an angle of 45° in line with the flow. More information is provided within the manual.
Max. Channel Width: 1.5 m (4.92 ft)
Beam Width: 20° inclusive
Options
Options: Description:
Velocity Interface For channels less than 1.5 m (4.92 ft) wide - provides a simple interface for the MicroFlow Sensor
FlowCERT & dBMACH3 Transducer For channels less than 1.5 m (4.92 ft) wide
dBMACH3, Ultimate Controller, Speedy velocity sensor For channels more than 1.5 m (4.92 ft) wide, more than one MicroFlow sensor is needed and can be combined with a dBMACH3 flow transducer and an Ultimate Controller with an optional Speedy sensor for a full open channel system
Mounting Brackets For easy installation
MicroFlow-i Optional loop powered version
Point connector Fitted to cable (with fuse)

    Approvals

  • CE Approval
  • ATEX Ex II 2 G D
  • ATEX Ex mb IIC T4 Gb
  • ATEX Ex mb IIIC T135 °C Db
  • ATEX Ta= -20 °C to +60 °C

Water

Wastewater

Food

Petrochemicals

Beverage

Oil and Gas

Power

Paper

×
Hello, I want to get information.