IMP + I.S Ultrasonic Level Sensor

  • Compact and self-contained level measurement
  • Simple menu led setup
  • High power and narrow beam angles
  • High specification ATEX
  • Up to 10 m (33 ft) range available

IMP+ I.S. is part of the Pulsar Measurement IMP family, a combined transducer and controller range in one self-contained unit. The IMP+ I.S. unit is certified to ATEX standard EEx ia IIC T4 and IECEx and available with the wetted parts in PVDF, making it ideal for measuring in corrosive or aggressive applications or anywhere where you need an accurate and reliable level measurement. The IMP+ I.S. benefits from our specially designed digital echo processing technique. The IMP+ I.S. are availble in three sizes from 3 m to 10 m (10 ft to 33 ft). With the benefit of the on board LCD display and keypad the IMP+ I.S. is straight forward to set up using the menu led programming.

• Tank Level Applications
• Chemical Dosing
• Simple Level Indication
• Open & Closed Vessel Level Requirements
• Solids Level Indication

General Specifications
Spec: Description:
Dimensions 186 mm H x 133 mm D (5.24 in H x 7.32 in D)
Cable Entry 2 x cable glands 4.5 mm to 10 mm (0.18 in to 0.39 in) (Torque to 2 NM)
Mounting IMP3 - 3 m (10 ft) version: 1.5 in BSP/NPT
IMP 6 - 6 m (20 ft) version: 1.5 in BSP/NPT
IMP10 - 10 m (33 ft) version: 2 in BSP/NPT
Suits BSP & NPT, parallel and tapered
Weight Nominal 1 kg (2.2 lb)
Enclosure Protection IP67
Temperature (Ambient) -40 °C to +6 5 °C (-40 °F to +149 °F)
Temperature (Process) -40 °C to +80 °C (-40 °F to +176 °F)
Input Voltage Range 11-30 V, 3.5-22 mA
Accuracy ±0.25% or 6 mm (0.24 in); whichever is greater
Resolution ±0.1% or 2 mm (0.08 in); whichever is greater
4-20mA Outputs Resolution 5 μA (both active and passive outputs)
Temperature Compensation Via internal temperature sensor (0.5 °C (± 32.9 °F) accuracy). Level and volume conversion are installed allowing linearisation for tank shapes.
PC Interface All parameters can be accessed and changed through PC Suite software. Echo traces may be viewed on-screen.
Options
Option: Description:
Variants IMP+
IMP Lite
Configurations 2-Wire or 3-Wire
Beam Angle (-3 dB half power) IMP3: ‹10° inclusive
IMP6: ‹10° inclusive
IMP10: ‹10° inclusive
Operating Frequency IMP3: 125 kHz
IMP6: 75 kHz
IMP10: 41 kHz
Measurement Range IMP3: 0.2 m to 3 m (0.66 ft to 10 ft)
IMP6: 0.3 m to 6 m (0.98 ft to 20 ft)
IMP10: 0.3 m to 10 m (0.98 ft to 33 ft)
Software IMP PC

Water

Wastewater

Food

Petrochemicals

Beverage

Oil and Gas

Power

Paper

×