Aktek Endüstriyel

Contact Us

DB Transducers Level, Volume, Flow

  • ATEX Zone 1 & 2
  • I.S. ATEX Zone 0 options
  • Integral temperature compensation
  • Narrow Beam Angles
  • Standard 2 or 3 core screened cable extensions to 1000 m (3,280 ft)
  • Patented DATEM (Digital Adaptive Tracking of Echo Movement) echo processing technology
  • FM/FMc Approval

Product Description

The dB ultrasonic range of transducers range from 3 m measurement range right up to 50 m measurement range and provide a reliable level, volume, open channel flow, pump control, and differential measurement, within both liquid and solids applications. The sensors benefit from highly accurate and repeatable ultrasonic technology and a low power design with standard interconnecting cables – producing extremely high acoustic power to give exceptionally high results in a wide variety of challenging applications.

The non-contacting design of the transducer means they can be fitted with zero interruption to service, and there’s no time consuming maintenance needed. We offer a wide range of options for our transducer range to suit the application. For example, a shield can be fitted during manufacturing to keep the transducer face clean and dry in applications at risk of submergence, PVDF versions of transducers are available for applications where there are chemicals present, and many more.

All dB Ultrasonic Transducers and dBR Radar Transducers are retrofittable with the Pulsar controller range, so if the needs for your measurement change, your measurement system won’t have to.

• Wet Well Level Measurement
• Tank Level Measurement
• Silo Level Measurement
• Pump Control Applications
• Shaft Tank Monitoring
• Digester Levels

General Specifications
Spec: Description:
Sensor body material Valox 357 U and syntactic foam face
Maximum separation 500 m (1,640 ft)
Mounting connection BSP or 1 in NPT
Enclosure protection IP68/NEMA 6P
Operating Temperature Standard: -40 °C to +90 °C (-40 °F to +194 °F)
Hazardous Area: -40 °C to +75 °C (-40 °F to +167 °F)
CE Approval 2014/30/EU - EMC & 2014/34/EU ATEX Directives. Standards applied: EN 60079-0:2012+A11:2013/ EN 60079-11:2012 / EN 60079-18:2009 / EN 60079-26:2007 / EN 61326-1:2013
ATEX Approval Standard ATEX EEx m II T6 or optional EEx ia IIC T6. FM/FMc approval. (dB50 not approved)
Accuracy 0.25% or 6 mm (0.24 in) whichever is greater
Resolution 0.01% or 2 mm (0.08 in) whichever is greater
Options
Option: Description:
PVDF Suitable for many applications where chemicals are present
Front threaded/PVDF Front threaded versions allow for easy mounting with 1.5 in or 2 in BSP/NPT nose thread
Submergence shield Keeps the transducer face clean and dry in applications at risk of submergence
Flanged DIN/ANSI Available in DIN or ANSI flange specification - all featuring PTFE coating on the process wetted side. Various flange sizes available
Foam Face Provides more acoustic power output in dry or dusty applications
Sanitary flange Includes a full face PVDF seal for use in hygienic applications
PTFE PTFE Coated on the wetted side
I.S. options All options available in I.S. option
Multiple Cable Lengths Available 5 m, 10 m, 20 m, 30 m (16 ft, 32 ft, 65 ft, 98 ft)
Accessories Additional aiming kit
Brackets A range of different stainless steel brackets are available to ensure the transducer is mounted in the best possible position for accurate results

Water

Wastewater

Food

Petrochemicals

Beverage

Oil and Gas

Power

Paper

×