- Description
- Specifications
- Brochure
- Userβs Guide
Product Description
Flexible packers are provided with a single-layer rubberized-fabric sleeve with metal faces with wheels at both its ends at an angle of 120Β°. The wheels ensure the stability of the packer in the pipeline. Its design allows water to flow freely during the repair. The effective surface ranges from 600 to 3500 mm. Their flexibility allows easy installation in the pipeline.
Type | Part β No. | Pipe diameter mm |
Rubber body diameter mm |
Rubber body length mm |
Total length mm |
Weight kg |
Operating pressure bar |
Bypass |
---|---|---|---|---|---|---|---|---|
FP 10/15β1 | 7209 | 100β150 | 65 | 1000 | 1120 | 1,9 | 2,5 | - |
FP 10/15β1,5 | 7211 | 100β150 | 65 | 1500 | 1620 | 2,3 | 2,5 | - |
FP 10/15β2 | 7210 | 100β150 | 65 | 2000 | 2120 | 2,6 | 2,5 | - |
FP 10/15β2,5 | 7212 | 100β150 | 65 | 2500 | 2620 | 2,9 | 2,5 | - |
FP 10/15β3 | 7213 | 100β150 | 65 | 3000 | 3120 | 3,3 | 2,5 | - |
FP 10/15β3,5 | 7214 | 100β150 | 65 | 3500 | 3620 | 3,7 | 2,5 | - |
FP 10/15β4 | 7215 | 100β150 | 65 | 4000 | 4120 | 4,0 | 2,5 | - |
FP 15/25β1 | 7201 | 150β250 | 105 | 1000 | 1180 | 5,0 | 2,0 | 2β |
FP 15/25β1,5 | 7216 | 150β250 | 105 | 1500 | 1680 | 6,3 | 2,0 | 2β |
FP 15/25β2 | 7202 | 150β250 | 105 | 2000 | 2180 | 7,5 | 2,0 | 2β |
FP 15/25β2,5 | 7217 | 150β250 | 105 | 2500 | 2680 | 8,8 | 2,0 | 2β |
FP 15/25β3 | 7218 | 150β250 | 105 | 3000 | 3180 | 10,0 | 2,0 | 2β |
FP 15/25β3,5 | 7219 | 150β250 | 105 | 3500 | 3680 | 11,3 | 2,0 | 2β |
FP 15/25β4 | 7220 | 150β250 | 105 | 4000 | 4180 | 12,5 | 2,0 | 2β |
FP 20/30β1 | 7236 | 200β300 | 144 | 1100 | 1340 | 10,0 | 1,5 | 2β |
FP 20/30β1,5 | 7237 | 200β300 | 144 | 1600 | 1840 | 11,1 | 1,5 | 2β |
FP 20/30β2 | 7238 | 200β300 | 144 | 2000 | 2240 | 12,2 | 1,5 | 2β |
FP 20/30β2,5 | 7239 | 200β300 | 144 | 2600 | 2840 | 13,3 | 1,5 | 2β |
FP 20/30β3 | 7240 | 200β300 | 144 | 3000 | 3240 | 14,4 | 1,5 | 2β |
FP 20/30β3,5 | 7241 | 200β300 | 144 | 3600 | 3840 | 15,5 | 1,5 | 2β |
FP 20/30β4 | 7242 | 200β300 | 144 | 4000 | 4240 | 16,6 | 1,5 | 2β |
FP 30/40β1 | 7203 | 300β400 | 235 | 1100 | 1340 | 19 | 1,5 | 2β |
FP 30/40β1,5 | 7221 | 300β400 | 235 | 1600 | 1840 | 21 | 1,5 | 2β |
FP 30/40β2 | 7204 | 300β400 | 235 | 2000 | 2240 | 23 | 1,5 | 2β |
FP 30/40β2,5 | 7222 | 300β400 | 235 | 2600 | 2840 | 26 | 1,5 | 2β |
FP 30/40β3 | 7223 | 300β400 | 235 | 3000 | 3240 | 28 | 1,5 | 2β |
FP 30/40β3,5 | 7224 | 300β400 | 235 | 3600 | 3840 | 31 | 1,5 | 2β |
FP 30/40β4 | 7225 | 300β400 | 235 | 4000 | 4240 | 33 | 1,5 | 2β |
FP 45/60β1 | 7205 | 450β600 | 365 | 1200 | 1440 | 36 | 1,0 | 4β |
FP 45/60β1,5 | 7226 | 450β600 | 365 | 1700 | 1940 | 40 | 1,0 | 4β |
FP 45/60β2 | 7206 | 450β600 | 365 | 2000 | 2240 | 42 | 1,0 | 4β |
FP 45/60β2,5 | 7227 | 450β600 | 365 | 2700 | 2940 | 46 | 1,0 | 4β |
FP 45/60β3 | 7228 | 450β600 | 365 | 3000 | 3240 | 49 | 1,0 | 4β |
FP 60/80β1 | 7207 | 600β800 | 365 | 1400 | 1640 | 37,5 | 1,0 | 4β |
FP 60/80β1,5 | 7229 | 600β800 | 365 | 1700 | 1940 | 41,5 | 1,0 | 4β |
FP 60/80β2 | 7208 | 600β800 | 365 | 2000 | 2240 | 43,5 | 1,0 | 4β |
FP 60/80β2,5 | 7230 | 600β800 | 365 | 2700 | 2940 | 47,5 | 1,0 | 4β |
FP 60/80β3 | 7231 | 600β800 | 365 | 3000 | 3240 | 50,5 | 1,0 | 4β |
FP 80/100β1,5 | 7235 | 800β1000 | 550 | 1800 | 2040 | 82 | 1,0 | 4β |
FP 100/120β2 | 7534 | 1000β1200 | 550 | 2200 | 2440 | 88 | 1,0 | 4β |
Technical Document
Safety Instruction Manual
Related Products
-
Request a QuoteQuick View
Portable Ultrasonic Transit Time Flow Meter TFM 1100P
- Backlit LCD Display
- Simple β16 key Calibration
- Built-in data-logger
- Β High accuracy measuring
- Wide measuring range from DN15 to DN6000
- RS-232 serial interface
-
Request a QuoteQuick View
Egg Shaped Pipe Stoppers UV, UVP
These pipe stoppers are used for sealing of egg-shaped sections.
-
Request a QuoteQuick View
Ultrasonic Slurry Flowmeter SFM 6.1
- Optimized for Slurries
- Easy, Intuitive Set-Up
- 5 Button Menu System
- Isolated 4-20mA Output
- Up to 6 Control Relays
- Optional Built In Data Logger
-
Request a QuoteQuick View
Electromagnetic Flow Meter MAGX2
MAGX2 offers a wide range of modules to allow each customer to βdesignβ their own solution for his application. The modules are βplug and playβ, can be easily installed or removed from the mother board (always check first that the unit is powered off) and have in most of the cases the size of a big postΒ stamp.
Arkon modules are divided in:
- Power supply modules.
- Output modules.
- Digital communication modules.
-
Request a QuoteQuick View
Area-Velocity Flow Monitor AVFM 6.1
- No flume or weir required β submersible ultrasonic sensor measures velocity and level simultaneously to calculate flow. No moving parts to wear, foul, or clog.
- Built-in 5-button keypad, intuitive menu, and large backlit LCD display make the AVFM 6.1 the most operator-friendly area velocity flow meter on the market.
- Fast, simple, installation and setup.
- Improved performance in a wider range of operating conditions.
- At a glance, view flow rate, velocity, level, totalizer, relay status, and important diagnostic information on the LCD display.
- Three isolated 4-20mA outputs for flow rate, velocity, and level, and two relay outputs for pulse output or alarm.
- 6.5 million point data logger for greater flexibility of data monitoring, control, and reporting.
- Min, Max, and Total Flow data from the last 365 days is available on the LCD display, or download directly to a USB for easy reporting.
- Monitors flow rate, volume total, run hours, and diagnostic information through only two wires with the optional Modbus RTU serial communication output.
-
Request a QuoteQuick View
Differential Level Transmitter DLT2.0
Measures Level, Differential Level and Open Channel Flow
Two Non-Contacting Ultrasonic Sensors
Large White Backlit LCD Display
Three Isolated 4-20mA Outputs
Built-in 5-Key Calibration
2 Programmable Control Relays
Optional 2 Million Point Data Logger
Optional Intrinsically Safe Sensors -
Request a QuoteQuick View
Sandwich Type Ultrasonic Water Meter TFMW-1
Sandwich Insertion Ultrasonic Water Meter is a new style water meter specially designed for Β agricultural irrigation, Garden Management and water resource supervision.
Advantages of this water meter ;
Low cost, high accuracy, low power consumption, stability and reliability.
1 inch thickness of the meter helps to save installation space, and parts to achieveΒ IP 68, enable the water works in any severe environment .
DueΒ to unique design, there will beΒ no pressure loss and different water medium will have no influence on measurement
Analog, Digital outputs and RS485
-
Request a QuoteQuick View
Stingray 2.0 Portable Level-Velocity Logger
- Measures water level and velocity in partially filled pipes and open channels
- No flume or weir required
- Extreme low power consumption Uses standard Alkaline D-cell batteries
- 130,000 point data logger
- USB output
- Powerful Windows software
- LCD bar graph display
-
Request a QuoteQuick View
MantaRay Portable Area-Velocity Flow Meter
- Measures flow in partially filled pipes and open channels
- No flume or weir required
- 4-20mA and Relay outputs for connection to Samplers and SCADA
- Powered with built-in rechargeable NiMH batteries
- 2 million point data logger with USB output to Flash drives
- Backlit LCD display for flow rate, totalizer and menu system
-
Request a QuoteQuick View
Mechanical Flow Meter Low Flow
-Water, De-Ionised Water
-Soluble Oils (Glycols)
-Petroleum Based Fluids
-Synthetic Based Fluids Coolants
-Corrosive Fluids Paints Solvents
-Air & Gases