Flow

  • N-Serie Mass Flowmeters

    Series N Mass Flow Sensor and IPT200 /  DPT100 transmitter are paired to constitute series N flow meter with accuracy in 0.2% or 0.15%.

  • P – Serie Mass Flowmeters

    P – Series Flow Meter consists of Series P Mass Flow Sensor and DPT Transmitter. The main features are as follows;

    • Applied to Liquids, Gases, Grout Mass Flow
    • Pipe sizes: DN10 – DN150
    • Flow Measuring Accuracy: ±0.1%
    • Density Measuring Accuracy: ±0.001g/cm2
    • Process Temperature Limits: -40°C…+200°C
  • Thermal Mass Flow Switch 7000NH – 7200NH

    Switch contact closure: 5 amp at 5 VDC & 115VAC
    Trip point accuracy: ± 1% of set point
    Fluid temperature range: -40° to 65°C
    Pressure rating, maximum: 500 PSI Std., > 500 PSI, special
    Input power requirement: 24 VDC @ 250 mA max., 230 VAC 50/50 Hz optional
    Flow Transmitter enclosure: IP66, 125 x 125 x 100 mm ABS plastic with polycarbonate cover
    Wetted materials: All 316 SS (ceramic, glass, & epoxy optional)

  • Thermal Mass Flow Meter 7000 – 7200 MP

    Switch contact closure: 5 amp at 5 VDC & 115VAC
    Trip point accuracy: ± 1% of set point
    Fluid temperature range: -40° to 65°C
    Pressure rating, maximum: 500 PSI Std., > 500 PSI, special
    Input power requirement: 24 VDC @ 250 mA max., 230 VAC 50/50 Hz optional
    Flow Transmitter enclosure: IP66, Aluminum enclosure
    Wetted materials: All 316 SS (ceramic, glass, & epoxy optional)

  • Thermal Mass Flow Meter 8000MP – 8100MP

    Outputs: 4 – 20mA, 0 – 5VDC
    Signal Interface: RS232 & RS485 Modbus RTU
    Accuracy: +/- 1%
    Gas Temperature Range: -40…+200C
    Power: 24VDC 250mA
    Display: 2 lines, 16 characters
    Keypad: 4-buttons
    Wetted Materials: 316 Stainless Steel (Hastelloy optional)
    Protection: IP66
    Traceable Calibration Certificate: NIST Standard
    ATEX Certificate: CE 0344; EX II 2GD / EEx d IIB + H2

  • Thermal Mass Flow Meter 8200MP

    Outputs: 4 – 20mA, 0 – 5VDC
    Signal Interface: RS232 & RS485 Modbus RTU
    Accuracy: +/- 1%
    Gas Temperature Range: -40…+200C
    Power: 24VDC 250mA
    Display: 2 lines, 16 characters
    Keypad: 4-buttons
    Wetted Materials: 316 Stainless Steel (Hastelloy optional)
    Protection: IP66
    Traceable Calibration Certificate: NIST Standard
    ATEX Certificate: CE 0344; EX II 2GD / EEx d IIB + H2

  • Thermal Mass Flow Meter 8600MP – 8700MP

    Outputs: 4 – 20mA, 0 – 5VDC
    Signal Interface: RS232 & RS485 Modbus RTU
    Accuracy: +/- 1%
    Gas Temperature Range: -40…+200C
    Power: 24VDC 250mA
    Display: 2 lines, 16 characters
    Keypad: 4-buttons
    Wetted Materials: 316 Stainless Steel (Hastelloy optional)
    Protection: IP66
    Traceable Calibration Certificate: NIST Standard
    ATEX Certificate: CE 0344; EX II 2GD / EEx d IIB + H2

  • Thermal Mass Flow Meter 8800 MP

    Outputs: 4 – 20mA, 0 – 5VDC
    Signal Interface: RS232 & RS485 Modbus RTU
    Accuracy: +/- 1%
    Gas Temperature Range: -40…+200C
    Power: 24VDC 250mA
    Display: 2 lines, 16 characters
    Keypad: 4-buttons
    Wetted Materials: 316 Stainless Steel (Hastelloy optional)
    Protection: IP66
    Traceable Calibration Certificate: NIST Standard

  • Thermal Mass Flow Meter 9000MP

    Outputs: 4 – 20mA, 0 – 5VDC
    Signal Interface: RS232 & RS485 Modbus RTU
    Accuracy: +/- 1%
    Gas Temperature Range: -40…+200C
    Power: 24VDC 250mA
    Display: 2 lines, 16 characters
    Keypad: 4-buttons
    Wetted Materials: 316 Stainless Steel (Hastelloy optional)
    Protection: IP66
    Traceable Calibration Certificate: NIST Standard

  • Miniature Variable Area Flow Switch

    • Complete stainless steel design
    • Universal mounting position
    • Small mounting dimensions
    • High switching accuracy
    • For low viscosity liquids
    • Small switch hysteresis
  • ultrasonic transit time flowmeter

    Ultrasonic Flowmeter/Calorimeter TFM3100 – F1

    The Transit Time Flow Meter TFM3100  measures flow rate by calculating the spreading time of an ultrasonic wave in a liquid, going upstream and downstream into a pipe.
    This flow meter is mostly used to measure the flow rate of homogeneous fluids, also with a quite high percentage of suspended solids.
    High accuracy measuring: Linearity: better than 0.5% Repeatability: better than 0.2%,  Accuracy: better than ± 1%
    Wide measuring range: Several types of transducers to be selected, measuring pipe sizes from DN15mm to DN6000mm with four different types of sensors + PT100 ohm when it works as heat meter.
    Italian or English menu: The different versions of TTFM100/2009 NEW GENERATION can support Italian or English display, easy to operate, in the near future other languages will be implemented.
    Power supply: 8….36 VDC or 10….30VAC
    Engineering Units: Flow: Imperial and metric – Calories: BTU; GJ; KW; KCal
    Dimensions / Protection Grade: 90 90 36mm / IP20
    Set-Up: By integrated keypad
    Output: Relay OCT/4-20mA/RS485
    Protocol: M-BUS, MODBUS
  • Ultrasonic Flowmeter TFM4100W

    Ultrasonic Flowmeter TFM4100W measures flow rate by calculating the spreading time of an ultrasonic wave in a liquid, going upstream and downstream into a pipe.
    This flow meter is mostly used to measure the flow rate of homogeneous fluids, also with a quite high percentage of suspended solids.