Electromagnetic Flow Meter MAGS1

Electromagnetic Flow Meter MAGS1

  • Auto-diagnostics
  • ±0.2% accuracy
  • Cable length up to 500m
  • Description
  • Application Areas
  • Specifications
  • Brochure
  • User’s Guide

Product Description

MAGS1 is a stand-alone version flowmeter, which does not need a transmitter and can be operated on its own.
If you need a low cost flowmeter without a read out on a display and outputs, this will be the right one.
Inexpensive solution for application with existing PLC System with RS485 Modbus RTU communication system.
No display; fully operational electromagnetic flowmeter. Cost-effective solution for installations where local display is not needed.

Water & Wastewater - distribution networks, irrigation, sludge/sewage, water treatment, desalination, marine, checking of pumps and water wells
Petrochemical/chemicals/sanitary - corrosive liquids, dosing of additives, chemicals, industrial water, waste water, potable water metering, food, pharmaceutical industry, medium and high density fluids, blending
Paper & Pulp - additives, bleaches, colorants, liquor

Power supply 24VDC ± 10% @ 0.5A max
Communication RS485 - Modbus RTU
Min. media electrical conductivity ≥5µS/cm, ≥20µS/cm for demineralized water
Flow range 0.1 to 10 m/s
Accuracy ±0.2% (0.5 to 10m/s) of actual value
Connection types DIN, ANSI, JIS flanged. Other types on request
Flange material Steel 1.0036 or higher, Dimensions acc. to DIN EN 1092-1, ASME B 16.5, JIS B 2239
Nominal size 25 – 250 mm (1”-10”)
Maximum nominal pressure PN40/300 psi
Max. media temperature 70°C (158°F) for Hard Rubber liner, 130°C (266°F) for PTFE liner Ambient temperature -20 to 60°C (-4 to 140°F)
Sensor protection IP68 (Nema 6), IP67 (Nema 5)
Liner Hard Rubber, PTFE, other material on request
Electrodes CrNi (Stainless) steel 1.4571 / 316Ti, other materials on request
Measuring tube Stainless steel 1.4301 dimensions according to EN 10027-2
Outer casing Carbon steel (1.0036) as standard External coating Lacquered finish (anticorrosive) Accessories options Earthing rings for plastic and lined pipes
Coils resistance 80/100 ohm
Other features:
Earthing through 3rd and 4th electrode
Automatic electrode cleaning
Empty pipe detection
Auto-diagnostics Test of excitation coils
Zero flow adjusting

Mag S1 brochure

Mags1 Brochure

Mag S1 electromagnetic flow meter user guide

Mag S1 electromagnetic flow meter user guide